Verify the Settings for the Application Calculation Regulation
The best way to check whether the CadnaA configuration is in line with specific rules is to apply the corresponding template and check whether there are any parameter that should have another configuration.
In the following example we will check the configuration of the CNOSSOS method:
1) After you have configured the CadnaA project, access Calculation/Settings:
2) Click on the green icon of the "Template" parameter and select the value2021/1226 Euof the parameter"Template" (more updated version of the CNOSSSOS method):
3) The lower window should show deviations from the configuration of the current CadnaA project from the CNOSSOS method rules.
(4)Subsequently, it will be necessary to verify the particularities of each project according to each region. For example, both Lden and Ln are calculated in Spain. In this case, it is necessary to configure CadnaA to calculate the 4 parameters and not just Lden and Ln as stipulated in the European Directive.
European Directive
Spanish legislation:
Related Articles
Automatic calculation of serial projects (batch processing)
WithCadnaAeit is possible to automatically calculate a mesh or individual receiving points for different projectsin series. This is the type of batch processing. The steps needed to configure batch processing are explained below: Change Command by ...
Model calculation taking into account thermal investment
So far, there is no calculation model that takes into account thermal investment, with the exception of the Nord2000. Neither ISO 9613-2 nor the CNOSSOS EU 1226/2021 calculation model consider it. Below is an image of the meteorology section using ...
Calculation of portions of meshes already calculated
Calculation of previously calculated mesh portions can be done using the toolMesh/Operations with Mesh... We will explain this below with an example: Suppose we have the following project with a calculated mesh: It is then intended to remove two ...
Calculation of acoustic parameters with SONarchitect
SONarchitect calculates the parameters based on models that are dealt with in paragraph 4 of ISO 12354-11. The DnT parameter is calculated from R', taking into account that T0 is 0.5, as extracted from the formula (7): SONarchitect calculates R' from ...
Calculate and Export Partial Level Table by Eighth Bands
Let us assume the following scenario in the there are 2 point sources, with the sound power spectrum allocated, 3 receivers and a calculation area around all the elements to be included in the calculation of partial levels: Then access the ObjectTree ...